Smarter fibre testing, without the complexity.
FlowScout SE100 simplifies fibre verification, cuts costs, and boosts technician safety—delivering fast, accurate results without the need for double-ended testing.

The FlowScout SE100 is purpose-built to verify fibre continuity and measure insertion loss using AFL’s 1430nm wavelength optical reflectors. When a reflector is detected, the device instantly measures insertion loss at 1430nm, while allowing other wavelengths like PON to pass through unaffected. This means reflectors can remain in place during normal network operation, enabling seamless testing without service disruption.

By combining an optical light source and power meter into one compact, cost-effective unit, the FlowScout SE100 allows a single technician to complete testing without the need for a second device or colleague. This not only reduces equipment and labour costs by over 50%, but also eliminates the time-consuming setup and coordination required for traditional double-ended testing. Fewer site visits and less time spent at subscriber premises translates into faster testing and fewer logistical challenges.

The SE100 enhances the customer experience by enabling remote testing from distribution panels or splitters, removing the need for on-site troubleshooting of FTTH drop issues. It also supports service providers’ goals to reduce costs through subscriber self-install ONT initiatives, helping avoid scheduling delays and access issues.

Technician safety is improved by eliminating repeated tower climbs, as testing can be performed from the distribution unit using reflectors installed at the radio unit. The SE100 also ensures test integrity with built-in detection for excess reflection and live fibres, alerting users to potential issues caused by damaged or dirty connectors. It’s a smarter, safer, and more efficient way to test fibre—without compromise.

 

Applications:

Used to verify:

  • FTTH continuity and insertion loss during service activation or troubleshooting
  • FTTA continuity and insertion loss between Distribution Unit (DU) and Radio Unit (RU)
  • Fiber backhaul continuity and insertion loss to demarcation point

Key Features

Here are some of the ways the FlowScout SE streamlines workflows and ensures reliable network performance.
Single-ended testing

Verifies fibre continuity and insertion loss at 1430nm using AFL Optical Reflectors so there’s no need for access at both ends.

Integrated test functions

Combines an optical light source and power meter in one compact unit to reduce reduce equipment needs and simplify field testing.

Reflection detection

Detects excess reflection and displays Optical Return Loss (ORL) to identify issues like dirty or damaged connectors.

Live fibre alerts

Automatically detects and notifies users of live fibres, preventing test errors and protecting network integrity.

Built-in CW reflectometer

Uses continuous wave reflectometry to instantly measure insertion loss to the reflector which ensures fast, accurate results.

Technical specification

FlowScout SE

Single-ended test set
EMITTER TYPE

Laser

SAFETY CLASS [1]

Class 1

FIBRE TYPE

Single-mode, compatible with all G.652, G.655, and G.657 SMF

CALIBRATED WAVELENGTH

1430nm and 1550nm

CENTRE WAVELENGTH

1430 ±5nm, 1550 ±20nm

SPECTRAL WIDTH (FWHM)

≤5nm

OUTPUT POWER LEVEL

-1 to -4dBm CW

OUTPUT POWER STABILITY

±0.1dB over 1 hour (after 1 minute warmup)

DETECTOR TYPE

InGaAs PIN

DETECTION RANGE

Reflector detected / not detected up to 20km (18mi) with optical loss ≤9dB at 1430nm & 1550nm and 1550nm ORL ≥25 dB

INSERTION LOSS MEASUREMENT RANGE

At least 10dB when ORL ≥25dB at 1550nm
At least 6dB when ORL in range 14–20dB at 1550nm

LOSS ACCURACY

±1.0dB for loss in range 0 to 6dB

LOSS RESOLUTION

0.1dB

MEASUREMENT UNITS

Loss in dB; ORL in dB

SIZE (IN BOOT)

14cm x 8.1cm x 3.8cm

WEIGHT

≤0.3kg

OPERATING TEMPERATURE

-10°C to +50°C, 0 to 95% RH (non-condensing)

STORAGE TEMPERATURE

-30°C to +60°C, 0 to 95% RH (non-condensing, batteries installed)

BATTERY POWER

2 x AA alkaline batteries, user-replaceable

AC POWER

Optional external AC power supply (100–240 VAC, 50–60 Hz; 5VDC at 2A)

BATTERY LIFE

Typical 120 hours, minimum 75 hours (continuous operation, backlight off)

DISPLAY

Backlit monochrome LCD

SHOCK AND VIBRATION

Drop test from 1 metre across 6 planes

OPTICAL PORT

Fibre-coupled, 2.5mm ceramic ferrule plus SC/APC connector adapter

DUCT CAP

Captive dust cap mounts over SC/APC connector adapter

NOTES

All specifications valid at 25°C unless otherwise specified. [1] FDA 21 CFR 1040.10 and 1040.11; IEC 60825-1:2014.

 

Make an enquiry

Fill in the form and one of our team will be in touch within 24 hours.
Start your search...
Search

Distributor Login

Please enter your credentials to log in